Prepare the
Fuser Unit
QMS magicolor 2 Op
eration9-6
3 Remove the oil bottle.
s Caution:
Hold a sheet of paper under the oil bottle as you remove
it, so no oil drips into the printer.
4 Place the oil bottle in an oil-proof container, such as a plastic
bag, until you’re ready to reinstall it.
5 Use an eye-dropper to remove any excess oil from the fuser.
Dispose of the oil following local safety laws and regulations.