Crown PIP-ISO Información técnica

Busca en linea o descarga Información técnica para Equipo de grabación Crown PIP-ISO. Crown PIP-ISO Technical information Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 43
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
LEVEL LEVEL
ON
OFF
30
27
24
21
18
15
12
9
6
3
0
ENABLECH1 CH2
ODEP
30
27
24
21
9
6
3
0
SIGNAL
/
IOC
18
15
12
LEVEL LEVEL
ON
OFF
30
27
24
21
18
15
12
9
6
3
0
ENABLECH1 CH2
ODEP
30
27
24
21
9
6
3
0
SIGNAL
/
IOC
18
15
12
LEVEL LEVEL
ON
OFF
30
27
24
21
18
15
12
9
6
3
0
ENABLECH1 CH2
ODEP
30
27
24
21
9
6
3
0
SIGNAL
/
IOC
18
15
12
Models:
Macro-Tech 600, 1200 & 2400
Macro-Tech 601, 1201 & 2401
Some models may be exported under the name
Amcron
.
®
102989-1
7/97
© 1997 by Crown International, Inc., P.O. Box 1000, Elkhart, IN 46515-1000 U.S.A. Telephone: 219-294-8000.
Fax: 219-294-8329. Macro-Tech amplifiers are produced by the Professional Audio Division of Crown
International, Inc. Trademark Notice:
SmartAmp
and
Grounded bridge
are trademarks and
Amcron
,
®
Crown
,
®
Macro-Tech
,
®
IOC
,
®
ODEP
,
®
IQ System
,
®
P.I.P.
®
and
TEF
®
are registered trademarks of Crown
International, Inc. Other trademarks are the property of their respective owners.
®
®
Commercial
Audio
LL 32521C
120 VAC North
American
Units Only:
Commercial
Audio
E106377
Approved for
THX Theatre
Systems
Vista de pagina 0
1 2 3 4 5 6 ... 42 43

Indice de contenidos

Pagina 1 - Units Only:

LEVEL LEVELONOFF302724211815129630ENABLECH1 CH2ODEP302724219630SIGNAL/IOC181512LEVEL LEVELONOFF302724211815129630ENABLECH1 CH2ODEP302724219630SIGNAL/I

Pagina 2 - FULL WARRANTY

Macro-Tech 600/1200/2400 Power AmplifiersPage 10If the air supply is unusually dusty, you might want topre-filter it using commercial furnace filters

Pagina 3 - IMPORTANT

Macro-Tech 600/1200/2400 Power AmplifiersPage 113.3 WiringThis section describes the most common ways to in-stall your amplifier in a sound system. T

Pagina 4 - CONTENTS

Macro-Tech 600/1200/2400 Power AmplifiersPage 123.3.2 Bridge-Mono OperationBridge-Mono mode is intended for driving loads with atotal impedance of 4

Pagina 5 - ILLUSTRATIONS

Macro-Tech 600/1200/2400 Power AmplifiersPage 13Fig. 3.6 Parallel-Mono WiringPARALLEL-MONO MODECH-2 CH-1CH-2 CH-1STEREOBRIDGEMONOPARALLELMONOINPUTSO

Pagina 6

Macro-Tech 600/1200/2400 Power AmplifiersPage 14Twin-lead shielded cable2-wire line cord(or battery power)Shield connectedto ground terminal3-wire gr

Pagina 7 - 1 Welcome

Macro-Tech 600/1200/2400 Power AmplifiersPage 15SOLVING INPUT PROBLEMSSometimes large subsonic (subaudible) frequenciesare present in the input signa

Pagina 8 - 2 Facilities

Macro-Tech 600/1200/2400 Power AmplifiersPage 16shielded pair cable is another effective way to reduceor eliminate hum resulting from inductive coupl

Pagina 9 - Macro-Tech 2400

Macro-Tech 600/1200/2400 Power AmplifiersPage 171. Note the load resistance of the loudspeakers connectedto each channel of the amplifier. Mark this

Pagina 10 - 3 Installation

Macro-Tech 600/1200/2400 Power AmplifiersPage 183.3.6 Additional Load ProtectionMacro-Tech amplifiers generate enormous power. Ifyour loudspeakers do

Pagina 11 - STEREO MODE

Macro-Tech 600/1200/2400 Power AmplifiersPage 194 Operation4.1 PrecautionsMacro-Tech amplifiers are protected from internal andexternal faults, but y

Pagina 12 - BRIDGE-MONO MODE

WORLDWIDESUMMARY OF WARRANTYThe Crown Audio Division of Crown International, Inc., 1718 WestMishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrant

Pagina 13 - PARALLEL-MONO MODE

Macro-Tech 600/1200/2400 Power AmplifiersPage 20The table in Figure 4.2 shows the possible states forthe ODEP and Signal/IOC indicators. It also desc

Pagina 14 - Single-conductor coax

Macro-Tech 600/1200/2400 Power AmplifiersPage 21and put the affected channels in standby. This protectsthe loads and prevent oscillations. The unit r

Pagina 15 - Input Wiring Tips

Macro-Tech 600/1200/2400 Power AmplifiersPage 224.3.4 Fuses and Circuit BreakersThe power supplies of the Macro-Tech 600 and 1200are protected by fus

Pagina 16 - Use Good Connectors

Macro-Tech 600/1200/2400 Power AmplifiersPage 23sensitivity to 0.775 volts for standard 1 kHz power.5. Replace the P.I.P. module and reconnect the po

Pagina 17

Macro-Tech 600/1200/2400 Power AmplifiersPage 24The two channels may be used together to double thevoltage (Bridge-Mono) or the current (Parallel-Mon

Pagina 18 - 3.4 AC Power Requirements

Macro-Tech 600/1200/2400 Power AmplifiersPage 25Fig. 5.1 Circuit Block DiagramFAULTONLY ONE CHANNEL SHOWNNPN HIOUTPUTSTAGENPN LOWOUTPUTSTAGEPNP LOWO

Pagina 19 - 4 Operation

Macro-Tech 600/1200/2400 Power AmplifiersPage 26The balanced gain stage (U104-C and U104-D)causes balanced to single-ended conversion using adifferen

Pagina 20

Macro-Tech 600/1200/2400 Power AmplifiersPage 276 SpecificationsThe following applies to units in Stereo mode with 8-ohm loads and aninput sensitivit

Pagina 21 - 4.3 Protection Systems

Macro-Tech 600/1200/2400 Power AmplifiersPage 28Stereo/Mono: A three-position back panel switch used toselect Stereo, Bridge-Mono or Parallel-Mono mo

Pagina 22 - 4.4 Controls

Macro-Tech 600/1200/2400 Power AmplifiersPage 29Crown specifications are guaranteed for three years.In an effort to provide you with as much informat

Pagina 23 - 4.5 Filter Cleaning

The information furnished in this manual does not include all of the details of design, production, or variations ofthe equipment. Nor does it cover e

Pagina 24 - 5 Technical Information

Macro-Tech 600/1200/2400 Power AmplifiersPage 3082Macro-Tech 2400 – Minimum Guaranteed Power (Watts)Stereo-MonoModeStereo(both channelsdriven)Bridge-

Pagina 25 - ONLY ONE CHANNEL SHOWN

Macro-Tech 600/1200/2400 Power AmplifiersPage 31Maximum Power SpecificationsCrown’s maximum power specifications represent the largest amount of outp

Pagina 26

Macro-Tech 600/1200/2400 Power AmplifiersPage 3282Stereo(both channelsdriven)Bridge-Mono(balanced output)Parallel-Mono1164468551535014751030675132510

Pagina 27 - 6 Specifications

Macro-Tech 600/1200/2400 Power AmplifiersPage 3310 100 1 K 10 K 100 KFREQUENCY (Hz)+2+10–1–2–3–4dB–5–6–74 ohm8 ohm1 watt504.0126.831.8MILLIOHMS8.02.0

Pagina 28 - Construction

Macro-Tech 600/1200/2400 Power AmplifiersPage 34TECHRONTEF®+45˚0˚–45˚100 1 K 10 K 20 KFREQUENCY (Hz)100 1 K 10 K 20 KFREQUENCY (Hz)dBTECHRONTEF®TEF®M

Pagina 29 - Macro-Tech 600 –

Macro-Tech 600/1200/2400 Power AmplifiersPage 35100 1 K 10 K 20 KFREQUENCY (Hz)dBTECHRONTEF®100 1 K 10 K 20 KFREQUENCY (Hz)dBTECHRONTEF®Fig. 6.12 Ty

Pagina 30 - Macro-Tech 1200 –

Macro-Tech 600/1200/2400 Power AmplifiersPage 367 AC Power Draw and Thermal DissipationThis section provides detailed information about theamount o

Pagina 31 - Maximum Power Specifications

Macro-Tech 600/1200/2400 Power AmplifiersPage 378 Ohm StereoL O A D50%40%30%20%10%5804853852851908957806605454258507005453952403102602151701251165

Pagina 32

Macro-Tech 600/1200/2400 Power AmplifiersPage 388 Accessories8.1 P.I.P. ModulesOne advantage of Macro-Tech amplifiers is the abilityto customize them

Pagina 33

Macro-Tech 600/1200/2400 Power AmplifiersPage 39CLPProgrammableInput Processor (P.I.P.)312GNDINPUT INPUTCH-2 CH-1PUSHPUSHP.I.P.–CLP detects and preve

Pagina 34 - Measurement

Macro-Tech 600/1200/2400 Power AmplifiersPage 4CONTENTS1 Welcome ... 71.1 Un

Pagina 35

Macro-Tech 600/1200/2400 Power AmplifiersPage 408.2 Cooling Fan OptionsEvery Macro-Tech amplifier has a built-in high-velocityfan that provides optim

Pagina 36 - Thermal Dissipation

Macro-Tech 600/1200/2400 Power AmplifiersPage 419 ServiceThis unit has very sophisticated circuitry which shouldonly be serviced by a fully trained t

Pagina 38 - 8 Accessories

Detach and send with unit.Crown Factory Service InformationShipping Address: Crown International, Inc., Factory Service, Plant 2 SW, 1718 W. Mishawaka

Pagina 39 - Technical Support Group

Macro-Tech 600/1200/2400 Power AmplifiersPage 5ILLUSTRATIONS1.1Macro-Tech Amplifier ...7

Pagina 40 - 8.2 Cooling Fan Options

Macro-Tech 600/1200/2400 Power AmplifiersPage 6

Pagina 41 - 9 Service

Macro-Tech 600/1200/2400 Power AmplifiersPage 71 WelcomeCongratulations on your purchase of the renownedMacro-Tech®professional power amplifier. Macr

Pagina 42

Macro-Tech 600/1200/2400 Power AmplifiersPage 8Fig. 2.1 Front FacilitiesLEVEL LEVELONOFF302724211815129630ENABLECH1 CH2ODEP302724219630SIGNAL/IOC181

Pagina 43 - NATURE OF PROBLEM

Macro-Tech 600/1200/2400 Power AmplifiersPage 9Fig. 2.2 Rear FacilitiesUNBALANCEDINPUT WIRINGBALANCEDINPUT WIRINGTHIS AMPLIFIER IS EQUIPPED WITH SEL

Comentarios a estos manuales

Sin comentarios