Crown IQ-PIP-USP2 CN Manual de usuario Pagina 2

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 2
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 1
Crown International
P.O. Box 1000
Elkhart, IN 46515-1000
TEL: 574-294-8200
FAX: 574-294-8FAX
www.crownaudio.com
12/02 134906-2
Crown’s Three-Year, No-Fault, Fully-Transferable Warranty
Crown offers a Three-Year, No-Fault, Fully-Transferable Warranty for every new Crown ampli-
er—an unsurpassed industry standard. With this unprecedented No-Fault protection, your new
Crown amplifi er is warranted to meet or exceed original specifi cations for the fi rst three years of
ownership. During this time, if your amplifi er fails, or does not perform to original specifi cations,
it will be repaired or replaced at our expense. About the only things not covered by this warranty
are those losses normally covered by insurance and those caused by intentional abuse. And the
coverage is transferable, should you sell your amplifi er.
See your authorized Crown dealer for full warranty disclosure and details. For customers outside
of the USA, please contact your authorized Crown distributor for warranty information or call
574-294-8200.
CTs 600
Clip Indicator: Red LED, one per channel,
illuminates when the channel’s output signal
reaches the onset of audible clipping. The Clip
Indicator also will illuminate during Thermal
Level Control (TLC) limiting or when the input
compressor/limiter is protecting the amplifi er
from input overload.
Thermal Indicator: Red LED, one per channel,
illuminates when the channel has shut down,
or is very near shutting down, due to thermal
stress or overload.
Fault Indicator: Red LED, one per channel,
ashes when the amplifi er output channel has
stopped operating.
Data Indicator: Yellow LED indicates IQ Loop
data activity (if the amplifi er is equipped with an
IQ-PIP2 module, and connected to an IQ Loop).
Power Indicator: Blue LED indicates amplifi er
has been turned on and AC power is available.
The LED will fl ash when the AC line voltage is
15% above or 25% below the nominal rated
value.
Cooling Vents: Front-to-rear forced airfl ow.
Power Switch: Push-on / push-off switch.
Back Panel Controls and Connectors
Power Cord Connector: Standard 15 amp IEC
inlet. Voltage is indicated above IEC inlet.
Reset Switch: Resets the circuit breaker that
protects the power supply.
Speaker Connectors: One four-pole touch-
proof terminal strip. Accepts up to 10 AWG
terminal forks.
Input Connectors: Balaced 3-pin terminal block
connectors, one per channel, on the standard
PIP
2
-BBY module.
Channel Level Control: One 21-position
detented rotary attenuator per channel, ranging
from minus infi nity (–70 dB) to 0 dB gain.
Mode Switch: Two-position switch is used to
select the amplifi er’s mode of operation: Dual or
Bridge-Mono.
Highpass Filter: One 3-position switch per
channel selects between OFF, 35Hz and 70Hz
3rd-order fi lters.
“Y” Input Switch: When set to ON, this switch
parallels the input signals of the two channels,
for use when the input signal is mono. Also
can be used to daisy-chain the signal to another
amplifi er.
Ventilation Grille: Front-to-rear forced airfl ow.
Options
PIP2 modules, including the IQ-PIP-USP2
and IQ-PIP-USP2/CN.
Protection Systems
Thermal Level Control (TLC): If an amplifi er
channel starts to overheat, the TLC system will
engage the input compressor. By compressing
the input, the amplifi er will not generate as
much heat and will have a chance to cool down.
The degree of compression is proportional to
the amount of overheating. This feature allows
the show to go on, rather than having the
amplifi er shut down.
Junction Temperature Simulation (JTS): JTS
circuitry simulates the operation of the amplifi -
er’s output transistors, and compares it against
the transistors known Safe Operation Area
(SOA). If JTS sees that more power is about
to be asked of the output devices than they are
capable of delivering under the present condi-
tions, JTS immediately limits the drive level
until it falls within the SOA. Limiting is propor-
tional and kept to an absolute minimum—only
what is required to prevent the possibility of
output transistor damage.
Fault: The amplifi er will light the Fault LED if
the amplifi er output stage stops operating.
AC Under/Over Voltage Protection: If the AC
line voltage drops below 25% or rises above
15% of the nominal operating voltage of the
amplifi er, the amplifi er’s power supply turns off
and the blue Power LED fl ashes. The amplifi er
will turn back on when the AC line voltage
returns to safe operating levels.
Circuit Breaker: This breaker protects the
amplifi er from excessive AC current draw.
DC Output Servo: The output servo circuit pro-
tects your drivers by eliminating DC offset, even
in the presence of very large asymmetrical sig-
nals.
Inrush Limiting: A soft-start circuit in the
power supply minimizes the amplifi er’s current
draw during power-on.
Variable-speed Fan: Two continuously variable
speed fans direct the airfl ow through the ampli-
er for cooling.
Specifi cations subject to change without prior notice. Latest
information available at www.crownaudio.com.
Crown, Com-Tech, IQ System and Multi-Mode are registered
trademarks and PIP2 is a trademark of Crown International.
Other trademarks are the property of their respective owners.
Printed in U.S.A.
© 2002 Crown Audio, Inc.